Create and Manage Specifications

This article is currently being updated. Please come back later for updates.

Specifications can be created, edited, and managed to define domains, variables, codelists, and methods. Specifications can be created manually or generated using Mapping Automation. When Mapping Automation is configured and data are imported and processed, elluminate automatically generates domains, variables, and Source Field mappings for SDTM specifications.

Create a New Specification

To create a specification, a name must be entered, a study selected, and a specification type chosen. Specification attributes can optionally be defined. If a standard is not selected during creation, it can be assigned later on the Domain page. Specification attributes can be edited at any time during the development process. After the specification is created, navigate to the Domain page to select domains for inclusion in the specification.  

  1. Access Specifications from the Platform Menu under Metadata Management.
  2. Click the Add icon in the toolbar.
    The Create Specification window opens. Fields are grouped into the General Information, Specification Configuration, and Code Generation sections. Fields with an asterisk are required.

    Create Specification window with fields grouped into General Information, Specification Configuration, and Code Generation sections, with Python, a Code Output Location folder, and SDTM set in the Code Generation section

  3. In the General Information section:
    1. Enter the Name of the specification. This is a required field.
    2. Enter a Description of the specification.
    3. Select the Study from the drop-down. Only studies accessible to the current user are displayed. This is a required field.
    4. Enter the Version Name.
    5. Enter Notes, as needed.
    6. Select the Requires Domain Approval checkbox if domains must be approved individually for the specification to be approved.
  4. In the Specification Configuration section:
    1. Select the Type from the drop-down: Mapping or Exception Listing.
    2. If Mapping is selected:
      1. Select the Standard from the drop-down: ADAM, CDASH, Custom, or SDTM.

        Important: If SDTM is selected and Mapping Automation is enabled with configured data stores and completed data processing, the specification is automatically generated using AI. Domains, variables, and Source Field values are created based on the selected standard and imported data. 

        Note: If a standard is selected during specification creation, domains can be selected only from that standard and version. To select domains from multiple standards, leave this field unselected. 

      2. Select the Standard Version from the drop-down. Available options are based on the selected standard.
      3. Select the Controlled Terminology Version from the drop-down. Available options are based on the selected standard and version. A message displays if required.
      4. Select the Therapeutic Area from the drop-down.
      5. Select the Dictionary version from the drop-down (i.e., MedDRA version).
      6. Select the Drug Dictionary version from the drop-down (i.e., WHO Drug version).
  5. If the Code Generation section displays, configure the code generation settings:

    1. Select the Output Language from the drop-down: Python, R, or SAS.
    2. Select the Code Output Location. This is the SCE folder where generated programs are saved.
    3. Select the Data Store from the drop-down. This is the data store where generated programs write output datasets.

    Note: For details on generating code, refer to the Generate Code from Specifications article in the Specifications section.

  6. Click Save.

After saving, the specification is listed first based on the default sort by Last Changed and is marked as Active. The Methods page includes a default list of mapping methods used for SDTM and ADaM data transformations.  

Specifications list sorted by Last Changed with the newly created JT Demo Spec listed first, selected, and marked as Active

Note: For details on managing Methods, see the Manage Methods in Specifications article.

Generate a Specification with Mapping Automation

Mapping Automation uses AI to generate domains, variables, and Source Field mappings for SDTM specifications.

This feature supports SDTM standards only.

Important: To configure and use Specification Mapping Automation, the Allow Specifications > Allow Mapping Automation URL setting must be enabled. Contact an eClinical Solutions representative for more details.

Configure Mapping Automation

  1. From the Study Details page, click the configuration icon to open the Edit Study window.
  2. Go to the Settings tab.

    Settings tab of the Edit Study window with the Statistical Computing Environment (SCE) and Mapping Automation toggles turned on and Clinical selected as the source data store

  3. Enable the Statistical Computing Environment (SCE). 
  4. Enable Mapping Automation.
  5. Select the Source Data Store(s) the model runs on by clicking in the field and selecting from the list.
  6. Click Save.

After configuration:

  1. Run a data import for the selected data store(s) to trigger the model.

The model runs for several minutes. When processing is complete, Mapping Automation is ready for use.

Note: Imports that introduce metadata changes in the selected data stores automatically trigger the model to run.

Tip: An audit log entry displays with the status Update Completed when processing finishes. This indicates the model is ready for use.

Mapping Automation

After data are imported into the selected data stores, the AI model runs automatically. When processing is complete, the model is ready for use.

To generate AI-enhanced specifications:

  1. Create a new specification and select SDTM as the standard. A message displays in the Create Specification window stating that the new specification is being enhanced with AI.

    Create Specification window with SDTM selected as the standard and a message stating that the new specification is being enhanced with AI

  2. Complete the specification setup.

After the specification is created:

  • The Domains list displays domains based on the selected standard version.
  • The Variables list is generated for each domain.
  • The Source Field column is automatically populated for applicable variables.
    Variable List for the AE domain of an SDTM specification with Source Field values populated by Mapping Automation

Important: When SDTM is selected, Mapping Automation generates the specification based on the configured model output. 

The AI-generated results can be modified or replaced as needed.

Note: Double-click any cell in the Variables list to edit values directly in-line. To view full variable details, select the row and click the Details icon in the toolbar. For more information, refer to the Manage Domains and Variables in Specifications article.

Edit a Specification

  1. Select the specification by selecting the row or the checkbox next to the specification.
  2. Click the Edit icon in the toolbar, or right-click the record and select Edit. The Edit Specification window opens with the current specification attributes grouped into the General Information, Specification Configuration, and Code Generation sections.
  3. Make updates as needed. All fields are editable except the specification type.
  4. Click Save to apply the changes.

    Edit Specification window with General Information, Specification Configuration, and Code Generation sections, showing the Type field unavailable and code generation settings populated

Important: Changing the Code Output Location after code is generated flags previously generated code as stale. Regenerate code to save updated programs to the new location.

Access Specification Details

Specifications list with the Details icon outlined and the Details view for JT Demo Spec showing specification attributes and the Domains, Codelists, and Issues sections with count badges and Go to buttons

  1. Select the specification by selecting the row or the checkbox next to the specification.
  2. Click the Details icon in the toolbar. The Details view opens.
    • Click the Close (X) icon to close the Details view.
    • Click the arrow to expand each section and view Domains, Codelists, or related Issues.
    • Blue badges next to Domains and Codelists indicate the number of items added. For Issues, the red badge indicates open issues, and the green badge indicates answered, closed, and canceled issues.
    • Click Go to Domains, Go to Codelists, or Go to Issues to navigate to the corresponding area.

Update the Status of a Specification

A specification defaults to the status of In Development. Use the Change Status icon to update the status as the specification progresses through review and approval cycles. To edit a specification, the status must remain In Development.

  1. Select the specification by selecting the checkbox next to the specification, or right-click the record.
  2. Click the Change Status icon in the toolbar, or right-click the row and select Change Status.
  3. Select the desired status from the menu.
    Change Status menu with In Development unavailable and the Submit for Review, Submit for Approval, and Approve options

Was this article helpful?

0 out of 0 found this helpful

Have more questions? Submit a request